UMG 96S2 - 5234002 Three-phase network analyzer with rated voltage up to 277/480 V AC. The supply voltage is common with the measurement voltage. RS 232, RS 485 interface, GridVis software.
239 € excl. VAT
289,19 € incl. VAT

Recycling fee 0,50 € included in the price

In stock
Order number: 5234002
EAN: 4251861100224

UMG 96-S2 is suitable for measuring and monitoring electrical parameters and energy consumption as well as for monitoring power quality parameters such as harmonics. It is suitable for measuring and controlling electrical variables, energy consumption as well as monitoring the power quality parameters, such as harmonics. It is used in energy distribution systems, for example, to record cost centres and monitor thresholds. In addition, the device can also be used as a measurement value sensor for building management systems or a PLC.

Universal area of application

  • Suitable for TN and TT networks with a 1 and 5 A transformer connection

High accuracy of measurement

  • Active energy with precision class 0.5S (.../5 A transformer)

Compact design

  • High performance in a compact 96 design with a low installation depth

Low efforts during integration

  • An open communication channel via Modbus RTU offers direct access into higher level networks

Low configuration requirements

  • Straightforward use with low configuration requirements

Visualization and documentation

  • Comprehensive options for data acquisition, visualizing and reporting through the GridVis®-Basic (network visualization software)

Compatibility

  • Low integration requirements due to high compatibility for conventional transformers

Tariff switching

  • Simple tariff conversion as additional building block for energy and cost transparency
Rated voltage [V] L-N: 50 - 300 V AC, L-N: 87- 520 V AC
Power voltage [V] společné s měřícím
Accuracy class 2
Width [mm] 96
Height [mm] 96
Depth [mm] 48
Weight in [g] 250
Software GridVis - Basic
Communication interface RS-485
Protocols Modbus RTU
Overvoltage category 300 V CAT III
Distortion factor THD-U, THD-I NO
Connection (L-N, L-L) 4 - conductive
Measurement type 4-quadrant
Current measurement channels NO
Digital inputs 2
Digital / pulse output 3
Sampling frequency 50/60 Hz 2,5 / 3 kHz
Number of measurement records per second 2.500/3000
Number of measuring results per second 1
Transients NO
Flicker measurement NO
Clock NO
Accuracy V/A 1,00 %
Integrated logic NE
Number of stored values ​​in memory NE
Weekly timer NE
Uninterruptible measurement NO
Short-term event outages (recording) NE
Measuring asymmetry NO
Residual current measurement NO
Recording of error events NE
Consecutive / backward / null component NE
Bi-metallic function ANO
Operating hours counter ANO
Input for temperature measurement Komparátory
RMS value of periods (50/60 Hz) 1/1

Accessories