UMG 96-PQ-L, 90-277V
We will be happy to advise you:
UMG 96-PQ-L, 90-277V
Whether power quality analysis, residual current monitoring or temperature monitoring, the UMG 96-PQ-L offers the right functions for every application. With the UMG 96-PQ-L, it is now possible to cost-effectively ensure complete power quality transparency at every level and thus avoid system failures.
Full-wave event measurements can be shown and analysed directly on the display. In addition, the modular network offers a large memory, which thanks to a special data compression method, ensures several years’ worth of storage.
Memory partitioning preserves the long term storage for current and power data and allows the combination of storing high-resolution power quality measurements. This storage partitioning helps extend the amount of data that is being stored at a higher performance while keeping costs of hardware low.
All values can be conveniently displayed and graphically represented on the color graphic display.
Power quality
- Harmonics current up to the 65th harmonic
- High sampling rate with 280 sampling points per full wave
- 1 ms digital input event capture rate
- 20 ms RMS value memory
- Full-wave events
Visualization
- Oscilloscope function
- Phasor diagram on the display
- Drag indicator history on the display
- Resetting of the drag indicators via display or remotely
Installation & Integration
- Overvoltage category 600 V CAT III
- Easy installation thanks to 96 x 96 mm front panel
- Use in IT networks with variants 52.36.005
- Time setting via third-party systems according to DIN 60970-5-4
Energy management
- Identify savings potentials
- Active energy class 0.2S#
- Compliance with regulatory and tax requirements
- Configurable screened average value
Memory
- High memory depth with low memory requirements
- Storage depth up to 15 years with 23 measured values of 15 min. each and 8 measured values of 1 h each
- Memory partitioning into long-term memory and high-resolution PQ shortterm memory
Modularity
- Temperature measurement with monitoring via integrated comparator
- Ethernet interface and Modbus gateway
- Multifunction inputs for residual current measurement or DC power measurement
- Neutral conductor measurement (I4 – current measurement)
Peripherals
- 3 digital outputs
- 1 analog output
- 3 digital inputs
Communication
- Modbus Client/Server gateway functionality
- Gateway function
- Ethernet interface
- RS485
- 5 simultaneous Modbus TCP connections
Operation
- 6-button operation on the color graphic display
- Intuitive operation
- Configuration directly on the display
- On-site and remote operation with GridVis®
- Configurable home screen and jump-back point
Comparator
- 50 comparators in the device
- Hysteresis
- Predefined comparator profiles for quick configuration (GridVis®)
Class S
- Flicker
- Interharmonics
- Standard-compliant PQ data based on, e.g. EN 50160 and IEEE519
- Rapid voltage change
- Overfrequencies & underfrequencies
- Predefined recording profiles for EN 50160, IEEE519,61000-2-4, AHF and SVG
| Rated voltage [V] | L-N: 600 v AC,L-L: v AC 720 v AC |
|---|---|
| Power voltage [V] | 90 - 277 V AC, 90 - 250 V DC |
| Width [mm] | 96 |
| Height [mm] | 96 |
| Depth [mm] | 86 |
| Weight in [g] | 250 |
| Software | GridVis - Basic |
| Communication interface | RS-485 |
| Protocols | Modbus RTU |
| Memory | 64 MB Flash |
| Overvoltage category | CAT II 300V, CAT III 600V |
| Distortion factor THD-U, THD-I | YES |
| Connection (L-N, L-L) | 3 / 4 - conductive |
| Measurement type | 4-quadrant |
| Current measurement channels | 1 |
| Digital inputs | 3 |
| Digital / pulse output | 3 |
| Sampling frequency 50/60 Hz | 13,67 kHz |
| Number of measurement records per second | 13.670 |
| Number of measuring results per second | 3 |
| Transients | NO |
| Flicker measurement | YES |
| Clock | YES |
| Accuracy V/A | 0,2 % / 0,2 % |
| Integrated logic | Jasic (7 Prg.) |
| Weekly timer | NE |
| Uninterruptible measurement | YES |
| Short-term event outages (recording) | ANO |
| Measuring asymmetry | NO |
| Residual current measurement | YES |
| Recording of error events | ANO |
| Consecutive / backward / null component | NE |
| Bi-metallic function | ANO |
| Operating hours counter | ANO |
| Input for temperature measurement | Komparátory |