UMG 604 E-PRO 230V (UL)

UMG 604 E-PRO 230V (UL) UMG 604 E-PRO 230V (UL) UMG 604 E-PRO 230V (UL)

We will be happy to advise you:

UMG 604 E-PRO 230V (UL)

UMG 604E - 5216202 Three-phase network analyzer with rated voltage up to 277/480 V AC. Supply voltage 95-240 V AC, 135-340 V DC. Flash memory, capacity 128 MB. Interfaces RS 232, RS 485, Ethernet, GridVis software.
907,25 € excl. VAT
1 097,77 € incl. VAT

Recycling fee 1 € included in the price

In stock
Order number: 5216202
EAN: 4251861102181

The UMG 604 is more than just a multifunction measurement device. It can be used to monitor the power quality and implement comprehensive energy management. Incorporation into the communication structure is possible with both devices, including by means of the Ethernet interface and the numerous IP protocols offered. In addition the UMG 604-EP PRO is equipped with an additional Profibus interface.

Harmonics occur due to operating equipment with a non-linear characteristic, e.g. transformers used in saturation, energy saving bulbs, frequency converters and power electronics. They cause a load on the mains due to additional currents and can affect or even destroy operating equipment. This mains feedback can be detected and documented using power quality analyzers.

The web server for the measuring device provides a wide range of data in a user-friendly format. The user does not have to install any software on their PC; a conventional web browser is all that is required. The user enters the measuring device IP address in the browser's URL bar and the measuring devices homepage is displayed on the screen. In addition to the modern homepage, APPs are available for an extended range of functions.

The user can use the graphical programming language Jasic® to add their own functions to a UMG measuring device. Up to seven freely configurable user programs can run in parallel, e.g. monitoring processes or notifications when reaching defined threshold values. In addition to the graphical programming option, the user is also free to program the source code directly in JASIC.

Events are short-term increases in voltage, dips in voltage, current swells or short-term interruptions (e.g. through bird strike or short circuits). UMG measuring devices can safely record and process events as of 20 ms and transients as of 50 μs. The causes of power quality variations can be identified and analysed in this way.

The Ethernet Modbus gateway can be used to easily include the Modbus RTU devices that are connected to the master device as slaves in an Ethernet architecture. This is also possible via a Modbus RTU interface for devices with identical file formats and matching function codes.

Many UMG measuring devices have their own memory containing typical recording ranges of up to 2 years. Recording is freely configurable. A 128 megabyte memory can record around 5,000,000 values.

Power quality

  • Harmonics analysis up to 40th harmonic
  • Unbalance
  • Distortion factor THD-U /THD-I
  • Measurement of positive, negative and zero sequence component
  • Short-term interruptions (> 20 ms)
  • Logging and storage of transients (> 50 μs)
  • Start-up processes
  • Fault recorder function
  • Rotary field indication

DIN mounting rail (6TE): Simple and cost-optimised installation

  • Mounting on a 35 mm DIN rail
  • Clear cost advantages in the switch cabinet construction through lower installation and connection effort
  • Simple integration into the LVDB, in machinery construction, in installation subdistribution panel for building management systems, in IT and in data centres

Modern communications architecture via Ethernet

  • Rapid, cost-optimised and reliable communication through integration into an existing Ethernet architecture
  • Integration in PLC systems and building management systems
  • High flexibility due to the use of open standards
  • Simultaneous polling of interfaces possible

Ethernet-Modbus-gateway and high-speed-Modbus

  • Simple integration of Modbus-RTU devices into an Ethernet architecture through the Modbus gateway function
  • Integration of devices with identical file formats and matching function codes possible via Modbus RTU interface
  • Fast and reliable data exchange via RS485 interface
  • Speed up to 921.6 kB/s

Graphical programming

  • Comprehensive programming options on the device, 7 programs simultaneously (PLC functionality)
  • Jasic® source code programming
  • Functional expansions far beyond pure measurement
  • Complete APPs from the Janitza library

Large measurement data memory

  • 128 MByte
  • 5.000.000 saved values
  • Recording range up to 2 years
  • Recording freely configurable
Rated voltage L-N: 277 V AC, L-L: 480 V AC
Power voltage 95 - 240 V AC, 135 - 340 V DC
Measurement type 4-quadrant
Distortion factor THD-U, THD-I YES
Overvoltage category 300 V CAT III
Current measurement channels 4
Digital inputs 2
Digital / pulse output 2
Communication interface RS-232, RS-485, Ethernet, Webserver / email
Memory 128 MB Flash
Sampling frequency 50/60 Hz 20 kHz
Connection (L-N, L-L) 3 / 4 - conductive
Number of measurement records per second 20.000
Measuring results per second 5
Transients 50 µs
Flicker measurement NO
Clock YES
Accuracy V / A 0,2 % / 0,25 %
Width [mm] 107,5
Height [mm] 90
Depth [mm] 82
Weight in [g] 350
Active energy accuracy class (kWh, .../5A) 0,5S (.../5 A) / 1 (.../1 A)
Integrated logic Jasic (7 Prg.)
Number of stored values ​​in memory 5.000 k
Software GridVis - Basic
Protocols BACnet (volitelný), SNMP, Modbus TCP/IP, Modbus RTU over Ethernet, Modbus - Gateway, Modbus RTU
RMS value of periods (50/60 Hz) 10/12
Uninterruptible measurement YES
Residual current measurement NO
Consecutive / backward / null component ANO
Measuring asymmetry YES
Recording of error events ANO
Bi-metallic function ANO
Weekly timer ANO
Operating hours counter ANO
Short-term event outages (recording) ANO
Input for temperature measurement 1