Universal measuring device UMG 96 RM

Variants of UMG 96RM

The UMG 96RM is available in different versions to meet the various application specific market requirements.

The differences between the variants are primarily with the interfaces, protocols and configuration of the inputs and outputs.

The basic device is already comprehensively equipped with a fast RS485 interface with Modbus protocol and 2 digital outputs.

All further variants are equipped with 4 digital inputs and 6 digital outputs, a clock, battery and memory as standard.

 

umg96rm-varianten-1_02Basic device

The fast RS485 interface with the Modbus protocol and the 2 digital outputs allows a quick and cost-effective monitoring of the power quality and energy consumptions.

umg96rm-varianten-2_01Profibus and digital IOs

The Profibus connection is particularly used in systems where the UMG 96RM is to be incorpora- ted into the automation environment (PLC controllers).

umg96rm-varianten-3_01Temperature input and analogue output

A multitude of inputs and outputs enable effective integration into upstream systems. Low voltage distribution systems, the transformer or the server cabinet can be protected from over-temperature simultaneously by means of the temperature input.

umg96rm-varianten-4_01M-Bus

The M-Bus field bus connection for the acquisition of consumption data collection from various different consumption meters, such as water, gas, heat or electrical current. The UMG 96RM can be simply and cost-effectively integrated into economical consumption data acquisition systems via the M-Bus connection or can be used as a data logger - even as the master device.

umg96rm-varianten-5_014th current transformer input

The increasing proportion of non-linear loads leads to increasing pollution effects on the grid, in particular overloading of the neutral conductor by harmonic currents. The N-line can be conti- nuously monitored through the 4th current input.

umg96rm-varianten-6_01

Ethernet (TCP/IP)

Increasingly communications are moving from typical field bus to Ethernet (TCP/IP). The UMG 96RM Ethernet connection guarantees a simple integration into the network and a fast and relia- ble communications architecture.

umg96rm-varianten-7_01Ethernet (TCP/IP) + digital and analogue IOs

Along with network transparency Smart Grid stands for the active control of energy flows and power. In addition the UMG 96RM offers a multitude of configurations for IOs for intelligent inte- gration and control tasks.